Article Text
Abstract
Background The contraceptive efficacy and tolerability of a new flexible extended regimen of ethinylestradiol (EE) 20 μg/drospirenone (DRSP) 3 mg to extend the menstrual cycle and enable management of intracyclic (breakthrough) bleeding (flexibleMIB) was investigated and the bleeding pattern compared with a conventional 28-day regimen and a fixed extended 124-day regimen.
Study design This Phase III, 2-year, multicentre, open-label study randomly (4:1:1) allocated women (aged 18–35 years) to the following regimens: flexibleMIB (24–120 days' active hormonal intake with 4-day tablet-free intervals); conventional (24 days' active hormonal intake followed by a 4-day hormone-free interval); or fixed extended (120 days' uninterrupted active hormonal intake followed by a 4-day tablet-free interval). Primary outcomes included the number of bleeding/spotting days during Year 1 (all regimens) and the number of observed unintended pregnancies over 2 years (flexibleMIB only).
Results Results were analysed in 1067 women (full analysis set). The mean number of bleeding/spotting days was lower with the flexibleMIB vs the conventional regimen [41.0±29.1 (95% CI 38.8–43.3) vs 65.8±27.0 (95% CI 62.2–69.4) days, p<0.0001; treatment difference −24.8 (95% CI −29.2 to −20.3) days]. The corresponding value for the fixed extended regimen was 60.9±51.1 (95% CI 53.9–67.9) days. The Pearl Index for the flexibleMIB regimen was 0.64 (95% CI 0.28–1.26). All regimens had comparable tolerability profiles.
Conclusions EE 20 μg/DRSP 3 mg administered as a flexible extended regimen with MIB is effective, well tolerated and is associated with statistically significantly fewer bleeding/spotting days and fewer withdrawal bleeding episodes vs EE/DRSP in a conventional 28-day regimen. The flexibleMIB also provided statistically significantly fewer spotting days vs EE/DRSP in a fixed extended 124-day regimen (post hoc evaluation). The flexibleMIB regimen allows women to extend their menstrual cycle and manage their intracyclic (breakthrough) bleeding.
This paper is freely available online under the BMJ Journals unlocked scheme, see http://jfp.bmj.com/info/unlocked.dtl
Statistics from Altmetric.com
Footnotes
-
Funding This study was funded by Bayer HealthCare Pharmaceuticals, Berlin, Germany, the manufacturer of of ethinylestradiol 20 μg/drospirenone 3 mg.
-
Competing interests Christine Klipping and Ingrid Duijkers are employees of Dinox BV, one of the centres in which the study was conducted. Michael P Fortier is a physician collaborating with the Clinique de Recherche en Santé des Femmes, one of the centres in which the study was conducted. Joachim Marr, Dietmar Trummer and Jörg Elliesen are employees of Bayer HealthCare Pharmaceuticals.
-
Provenance and peer review Not commissioned; externally peer reviewed.